https://www.thermofisher.com/order/catalog/product/4315931#/4315931
Genetic analyzer that performs fragment analysis and rapid sequencing applications. Usage per array is 100 runs with use of Applied Biosystems reagents.
Proper citation: Thermo Fisher: Applied Biosystems: 3130xl Capillary Array (RRID:SCR_018048) Copy
https://www.thelabworldgroup.com/ge-typhoon-9410-microarray-imager
Variable mode imager that operates in three different modes, including phosphorescence, fluorescence, and chemiluminescence. Can scan in visible range using reflected light. Scanning resolution ranges from 1000um down to 10um. Scanning software is linked to ImageQuant TL 7.0 analysis software. ImageQuant is capable of quantifying Typhoon images such as those from Northern or Western blots. Images can be saved in various formats and imported into Powerpoint slides. Instrument has three excitation lasers (532nm, 633nm, 488nm). Instrument utilizes 536SP, 670BP, 520BP emission filters for fluorescence. For DNA, RNA and protein samples you may choose from: storage phosphor auto-radiography, direct blue-excited fluorescence (457-488 nm), direct green-excited fluorescence (532 nm), direct red-excited fluorescence (633 nm), and chemiluminescence.
Proper citation: GE: Healthcare: 9410 Variable Mode Imager (RRID:SCR_018047) Copy
https://www.leicabiosystems.com/histology-equipment/microtomes/products/leica-rm2265/
Automated rotary microtome that sections tissue samples. Specimen feed system with zero-backlash and maintenance-free cross roller guides and stepper motor operated coarse feed system are located in dust-proof plastic housing. Equipped with safety handwheel with handle that can be centered, as well as mechanical handwheel lock. In manual operation retraction can be adjusted. In motorized operation retraction value varies with selected sectioning speed.
Proper citation: Leica: Biosystems RM2265 Fully Automated Rotary Microtome (RRID:SCR_018041) Copy
https://www.thermofisher.com/order/catalog/product/313001R#/313001R
Genetic analyzer can run sequencing and fragment analysis applications including microsatellite analysis, AFLP, LOH, SNP validation, and SNP screening. Maintenance time is reduced by eliminating manual syringe washing and filling with automated polymer delivery. Can increase data quality for sequencing and fragment analysis applications by longer read length, and higher resolution with shorter run times. Uses 96- or 384-well plates with four capillary array.
Proper citation: Thermo Fisher: Applied Biosystems: 3130 Genetic Analyzer (RRID:SCR_018046) Copy
https://timothyspringer.org/files/tas/files/biacore3000-instrument.pdf
Biacore 3000 processing unit is an established, label-free system for detailed studies of biomolecular interactions. The system delivers comprehensive characterization of the interaction, answers questions about the rate constants, affinity, specificity, and determines the active concentration of components. The ability to recover and transfer interaction partners directly to MALDI targets for identification and further characterization makes the system highly applicable to fast identification of unknown interactants.
Proper citation: GE: Biacore 3000 Real Time Biomolecular Interaction Analyzer (RRID:SCR_018044) Copy
Bioanalyzer system is automated electrophoresis tool that provides an analytical evaluation of various samples types in many workflows, including next generation sequencing NGS, gene expression, biopharmaceutical, and gene editing research. Digital data is provided in timely manner and delivers assessment of sizing, quantitation, integrity and purity from DNA, RNA, and proteins. Minimal sample volumes are required for accurate result, and data may be exported in many different formats.
Proper citation: Agilent: 2100 Bioanalyzer Instrument (RRID:SCR_018043) Copy
http://www.thunderbiosci.co.kr/wp-content/uploads/2017/07/Apollo-324_brochure.pdf
Compact benchtop platform that enables rapid and full walk-away automation of next generation sequencing applications. Paired with PrepX reagents, Apollo 324 line offers complete sample-toanswer solution for NGS library prep. Apollo 324 automated protocols and PrepX reagent kits combine liquid handling and proven chemistries to produce high quality libraries for all major NGS platforms. System provides complete, walkaway solution using validated protocols and chemistries that produce consistent libraries for DNA-seq, RNA-seq, and ChIP-seq applications.
Proper citation: Wafergen: Apollo 324 NGS Library Prep (RRID:SCR_018027) Copy
https://www.selectscience.net/products/gel-logic-212-pro/?prodID=83511#tab-2
Automated gel imaging system for imaging fluorescence or colorimetric data in sample formats such as gels (DNA/Coomassie/Silver stain) membranes, and 96 well plates. Features include autofocusing and directed autoexposure.
Proper citation: Select Science: Carestream Gel Logic 212 PRO Imaging System (RRID:SCR_018029) Copy
https://www.sonybiotechnology.com/us/instruments/sh800s-cell-sorter/
Benchtop cell sorter that sorts wide range of cell sizes for many applications using microfluidic sorting chips. Integrated with comprehensive fluidics controls and advanced automation for set-up, acquisition, sort and analysis. System software supports sorting into tubes and 96- and 384-well plates. Software generates FCS 3.0 and FCS 3.1 files that can be exported to third party analysis tools. For non-clinical research use only. For applications in which cross-contamination is concern, optional e-beam sterilized consumables can be used to replace sample line and sorting chip. Optional class A2 Level II biosafety cabinet provides protection for personnel and products. Biosafety cabinet meets international standards.Optical design offers up to four collinear excitation lasers (488 nm, 405nm, 561nm and 638nm) and six fluorescence detectors. The six free-form PMTs enable detection of fluorescence signals from any laser based on filter selection.
Proper citation: Sony biotechnology: SH800S Cell Sorter (RRID:SCR_018066) Copy
THIS RESOURCE IS NO LONGER IN SERVICE. Documented on November 14,2023.Automated preparation system that isolates and prepares single cell templates for analysis. It can analyze mRNA and DNA sequencing, epigenetics or miRNA expression. It can extract, reverse transcribe, amplify, and analyze gene expression.
Proper citation: Fluidigm: C1 Single-Cell Automated Preparation System (RRID:SCR_018578) Copy
https://www.marshallscientific.com/Fisher-Scientific-PowerGen-125-Homogenizer-p/fs-pg125.htm
Homogenizer with speeds from 8,000 to 30,000 RPM for volumes of up to 100ml. Homogenizer for production of dispersions and emulsions, plant tissues, human tissues, animal tissues, resins, and pigments.
Proper citation: Thermo Fisher: n125 Homogenizer (RRID:SCR_018576) Copy
https://www.gilson.com/verity-271-hplc-system.html
HPLC liquid handler with midsize bed capacity and fraction collector. It has maximum flow rates up to 200 mL per min, injection loop volumes of 2 uL to 25 mL, and max sample mass of 15 grams per injection.
Proper citation: Gilson: GX-271 HPLC System (RRID:SCR_018579) Copy
https://www.ttuhsc.edu/pharmacy/research/documents/Amnis-Imagestream-Manual.pdf
Bench top multispectral imaging flow cytometer designed for the acquisition of up to 12 channels of cellular imagery. It combines per cell information with statistical significance of sample sizes of standard flow cytometry.
Proper citation: Luminex: Amnis ImageStreamX Mk II System (RRID:SCR_018589) Copy
https://www.illumina.com/documents/products/datasheets/datasheet_cbot.pdf
Genetic amplifier that uses amplification to create single molecule DNA templates and dispense reagents. It also controls reaction times, flow rates, and temperatures.
Proper citation: Illumina: cBot Genetic Amplifier (RRID:SCR_018580) Copy
https://www.kentscientific.com/products/coda-high-throughput-system/
CODA mouse rat tail-cuff system was designed to allow accurate blood pressure measurement in mice and rats. Blood pressure is measured in the tail of the mouse or rat using Volume Pressure Recording (VPR) sensor technology. Using the included software allows you to continuously view data in real-time.
Proper citation: Kent Scientific: Coda Blood Pressure System (RRID:SCR_018585) Copy
https://www.agilent.com/cs/library/brochures/5990-5596EN.pdf
Agilent 3100 OFFGEL Fractionator performs isoelectric focusing of proteins or peptides in immobilized pH gradient (IPG) gel strips.
Proper citation: Agilent: 3100 OFFGEL Fractionator (RRID:SCR_018433) Copy
https://mobile.labwrench.com/equipment/8044/applied-biosystems/voyager-de-pro
Benchtop MALDI TOF mass spectrometer that has linear and reflector analyzer. It is used to analyze organic and inorganic compounds, protein identification, synthetic peptide validation, and polymer analysis.
Proper citation: Thermo Fisher: Applied Biosystems: ABI Voyager DE Pro MALDI-Mass Spectrometer (RRID:SCR_018432) Copy
https://www.mpbio.com/fastprep-24-5g-instrument
Sample disruption instrument that can homogenize, grind, or lyse biological samples. Samples are added to individual lysing matrix tubes and shaken in tridimensional motion.
Proper citation: MP Biochemicals: FastPrep24 Sample Preparation (RRID:SCR_018599) Copy
https://www.thelabworldgroup.com/mettler-toledo-pb303-precision-balance
Miligram balance that is used for weighing, tarring, percent weighing, and dynamic weighing for unstable samples. Has maximum capacity of 310 grams. Lab balance utilizes mono block weighing technology with permanent shock protection and built in overload protection as well as automatic calibration.
Proper citation: Mettler: PB303-S Milligram Balance (RRID:SCR_018592) Copy
Invitrogen benchtop automated cell counter. Can perform cell counts, viability calculations, hemocytometry, fluorescent protein expression, and measure fluorescence capabilities. There are also reusable slides, fluorescence capabilities, and brightfield fluorescence channels.
Proper citation: Thermo Fisher: Life Technologies: Countess Automated Cell Counter (RRID:SCR_018591) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the dkNET Resources search. From here you can search through a compilation of resources used by dkNET and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that dkNET has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on dkNET then you can log in from here to get additional features in dkNET such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into dkNET you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within dkNET that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.