Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
Jeff Hodgin 2019. U Michigan - Glomerular Filtration Rate Determination with Minipump Inulin Clearance. protocols.io dx.doi.org/10.17504/protocols.io.x63frgnCopy Citation Copied
URL: https://dx.doi.org/10.17504/protocols.io.x63frgn
Authors: Jeff Hodgin
Group: Mouse Metabolic Phenotyping Centers
Summary: This is the protocol for measuring Glomerular Filtration Rate (GFR) with minipump FITC-inulin clearance in mice. In brief, Alzet micro-osmotic pumps (minipumps, Model 1007D) are filled with 3% FITC-inulin solution. These pumps release FITC-inulin at a rate of 0.5 μl/hr at least seven days. Mouse is temporarily anesthetized and then two mini-pumps are implanted in mouse peritoneal cavity through a tiny midline incision. After surgery, 24-hour urine is collected with metabolic cage and 100 μl of blood from saphenous vein is obtained at the same time. The concentrations of FITC-inulin in urine and blood samples are measured by flurometer and GFR is calculated by the concentration of FITC-inulin in 24-hour-urine and the concentration of FITC-inulin in plasma.
Affiliations: University of Michigan - Ann Arbor
External URL: https://mmpc.org/shared/document.aspx?id=310&docType=Protocol
Version: 1
Publication Date: 2019