Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
Kentaro Itokawa, Tsuyoshi Sekizuka, Masanori Hashino, Rina Tanaka, Makoto Kuroda 2020. nCoV-2019 sequencing protocol for illumina. protocols.io dx.doi.org/10.17504/protocols.io.bnn7mdhnCopy Citation Copied
URL: https://dx.doi.org/10.17504/protocols.io.bnn7mdhn
Authors: Kentaro Itokawa, Tsuyoshi Sekizuka, Masanori Hashino, Rina Tanaka, Makoto Kuroda
Group: Coronavirus Method Development Community
Summary: This protocol is folked from "ARTIC amplicon sequencing protocol for MinION for nCoV-2019" by Josh Quick to adapt it to illumina sequencers. In this Version V3, the reverse-transcription step was changed to use of NEB's LunaScript RT SuperMix Kit instead of Thermo Fisher's SuperScript IV Reverse Transcriptase as adapting to the recent update of ARTIC Network's protocol (LoCost). Tyson et al., Improvements to the ARTIC multiplex PCR method for SARS-CoV-2 genome sequencing using nanopore bioRxiv2020.09.04.283077;doi:https://doi.org/10.1101/2020.09.04.283077 Because the PCR products are fragmented before ligated with adapters, this protocol is compatible to many sequencing kits with various read lengths (75PE, 150PE, etc.) in Illumina machines. While the library preparation uses QiaSeq FX by Qiagen and is basically straight forward (as par kit instruction but modified to 1/4 scale), some tweaks for much of simplicity and speed were added.Change histories (V2): The amount of cDNA input to multiplex PCR is increased (now almost same amount to the ARTIC Network's original protocol) (Step 10). This change gives better results for samples with extremely low RNA copy. Amount of adapter solution input was corrected (Step 19).Change histories (V3): RT step has been changed to use of LunaScript (Tyson et al., 2020).Corrected typos and wrong descriptions about amount of reagents.Added a link to library quantification protocol.Other minor changes.Change histories (V3): RT step has been changed to use of LunaScript (Tyson et al., 2020).Corrected typos and wrong descriptions about amount of reagents.Added a link to library quantification protocol.Other minor changes.
Affiliations: National Institute of Infectious Diseases, Japan, National Institute of Infectious Diseases, Japan, National Institute of Infectious Diseases, Japan, National Institute of Infectious Diseases, Japan, National Institute of Infectious Diseases, Japan
Version: 3
Publication Date: 2020
Expand AllComing soon.
Source: Protocols.io