https://www.bruker.com/products/infrared-near-infrared-and-raman-spectroscopy/raman/multiram.html
Spectrometer with OPUS software that controls data collection and manipulation functions for MultiRAM. Real time spectrum display permits software control of analysis conditions, including optimization of laser power and sample position.
Proper citation: Bruker: MultiRAM Raman Spectrometer (RRID:SCR_019785) Copy
Gas analyzer with a 19-inch rack mount box that is equipped with 5 m multi reflection gas cell, spectral resolution, TE cooled detector for sensitivity without need for liquid nitrogen, nickel plated gas cell and gold coated mirrors that enable measurement of corrosive gases, and accounts for variable pressure and temperature of gas by sensors included inside gas cell.
Proper citation: Bruker: OMEGA 5 Gas Analyzer (RRID:SCR_019786) Copy
Preset and manual controls for UV or time exposure settings. Internal microprocessor measures and controls UV output, ensuring maximum energy efficiency. Consistent crosslinking takes seconds with 8W shortwave UV tubes. Select shortwave for sterilization and bonding DNA; midrange for gel electrophoresis; or long wave for UV curing. Crosslinker has maximum energy setting of 999,900 �J/cm2. Uses five 8W UV tubes. Digital LED displays settings. Viewing window blocks UV while allowing visibility of chamber interior. An internal interlocking safety system is designed for automatic shutoff when the door is opened. 115V, 60Hz; ETL-/ETLc-certified. External dimensions (D x W x H) in. (cm): 13.7 x 15.6 x 8.75 (34.8 x 39.6 x 22.2).
Proper citation: Spectrum Chemical: CL-1000 UV Crosslinker CL-1000 (RRID:SCR_019820) Copy
Microscope that combines dual views with dual detection channels for large scale 3D imaging of life specimens and cleared samples. System enables transition between living and cleared tissue imaging.
Proper citation: Bruker QuVi SPIM Light-Sheet Microscope (RRID:SCR_019788) Copy
https://covaris.com/products/afa-ultrasonication/r230/
Focused ultrasonicator that can be fully integrated on many liquid handler platforms with high throughput sample processing with AFA energetics and AFA TUBE TPX plates.
Proper citation: Covaris: R230 Focused-Ultrasonicator (RRID:SCR_019821) Copy
https://www.labx.com/product/bruker-corporation-microtof-q-ii
Benchtop Q-Tof, applied to a variety of applications such as small molecule accurate mass determination (HRMS), intact protein analysis including antibodies, peptide mapping, and other custom projects. This system is operated with an Agilent 1260 UPLC and includes an inline diode array detector and ESI source.
Proper citation: Bruker: micrOTOF-Q II Liquid Chromatography Mass Spectrometer (RRID:SCR_019781) Copy
Dairy analyzer that can analyze parameters like fat, protein, total solids and lactose. High pressure homogenizer provides evenly homogenized samples for repeatability and accuracy. Can also determine freezing point.
Proper citation: Bruker: MIRA Infrared Milk Analyzer (RRID:SCR_019782) Copy
MultiMode 8-HR is an atomic force microscope which is well suited for imaging in both air and fluid. Heating to 250C, cooling to -35C with temperature control accessories. Nanothermal analysis for local polymer phase transition temperatures up to 350C.. Atomic resolution electrochemistry with AFM, STM, and SECPM. Invent your own mode by accessing and modifying any signal, high or low voltage. A large variety of standard operating modes and many capabilities enable the MultiMode 8-HR AFM system to characterize everything from mechanical to electrical properties
Proper citation: Bruker: Multimode 8 Atomic Force Microscope (RRID:SCR_019783) Copy
Mass spectrometer that is designed for automated protein identification and characterization, biomarker detection, oligonucleotide quality control, and SNP genotyping.
Proper citation: Bruker: MicroFlex MALDI Microflex Mass Spectrometer (RRID:SCR_019780) Copy
Scanning imaging remote sensing system that allows identification, quantification, and visualization of potentially hazardous gas clouds from long distances. It is based on the combination of an infrared spectrometer with a single detector element and a scanner system.
Proper citation: Bruker: SIGIS 2 Remote Sensor (RRID:SCR_019797) Copy
Multiphoton microscope that is designed for intravital imaging, with fully motorized control of objective X-Y-Z position, as well as two axes of rotation for precise imaging orientation. Second scan path enables simultaneous imaging and photoactivation.
Proper citation: Bruker Ultima 2Pplus Multiphoton Microscope (RRID:SCR_019798) Copy
MALDI (Matrix Assisted Laser Desorption/Ionization) tandem mass spectrometer specially designed for automated MS and MS/MS high throughput identification of proteins and peptides. Tandem Mass Spectrometry is a technique that utilizes more than one mass selective stage in a mass spectrometer.
Proper citation: Bruker: Ultraflex III MALDI TOF/TOF Mass Spectrometer (RRID:SCR_019799) Copy
WDXRF spectrometer that features compact WDXRF goniometer, closely coupled optics, and 400 W direct excitation power. It has linear range of more than two Million cps based on HighSense XE detector.
Proper citation: Bruker: S6 JAGUAR WDXRF (RRID:SCR_019792) Copy
https://www.bruker.com/products/infrared-near-infrared-and-raman-spectroscopy/raman/ram-ii.html
Add-on module that can be coupled to a research spectrometer and allows automated switching between FT Raman and FT IR measurements.
Proper citation: Bruker: RAM II FT Raman Module (RRID:SCR_019795) Copy
Analyzer that is used for the determination of the mean fat globule size in milk and liquid milk products as well as in dissolved milk powders.
Proper citation: Bruker: GLOBULYSER Homogenizer Efficiency Analyzer (RRID:SCR_019767) Copy
Microscope that has been optimized for long term 3D fluorescence imaging of living specimens.
Proper citation: Bruker: InVi SPIM Light-Sheet Microscope (RRID:SCR_019768) Copy
https://www.bruker.com/products/mass-spectrometry-and-separations/maldi-toftof/ultraflextreme.html
Smartbeam-II laser enables ultra-high data acquisition speed in both MS and MS/MS at full systems performance. The well-established proprietary smartbeam laser provides unprecedented analytical and matrix flexibility in workflows from protein tissue imaging, intact proteins analysis, Glycoproteomics, biologics or oligo QC, to LC-MALDI proteomics - all fully enabled at 1-2000 Hz repetition rates. Bruker's patented smartbeam technology is already widely accepted as the most viable MALDI imaging laser technology. The new ultrafleXtreme now enables low pixel sizes for high spatial resolution imaging. Importantly, outstanding spectral quality and signal intensity are maintained at even the smallest laser beam diameters.
Proper citation: Bruker: ultraXtreme X-Ray Imaging System (RRID:SCR_019801) Copy
Imaging remote sensing system that is based on combination of Michelson interferometer and focal plane array detector. Each pixel of array records interferogram from corresponding field of view. System allows identification, quantification and visualization of potentially hazardous gases from long distances.
Proper citation: Bruker: HI 90 Remote Sensor (RRID:SCR_019769) Copy
Spectrometer that is used for remote sensing of chemical substances in atmosphere.
Proper citation: Bruker: EM27 Remote Sensor (RRID:SCR_019766) Copy
D8 ADVANCE is a real quick-change artist that can be configured to take on a single analytical task with great focus and dedicated components, or a fully featured, multi-purpose solution that is capable of dealing with very diverse analytical needs with highest competence. Our famous DAVINCI design ensures for all those solutions easy (re)configuration and extensibility to exactly satisfy your analytical needs, now and in the future. XRD data are typically collected in one direction, 2Theta. Simultaneously collecting data along a second dimension, the Gamma direction, can speed up data collection and provide additional information about the properties of crystalline samples, such as texture, residual stress, grain size and epitaxial relations.
Proper citation: Bruker: D8 Advance XRD (RRID:SCR_019761) Copy
Can't find your Tool?
We recommend that you click next to the search bar to check some helpful tips on searches and refine your search firstly. Alternatively, please register your tool with the SciCrunch Registry by adding a little information to a web form, logging in will enable users to create a provisional RRID, but it not required to submit.
Welcome to the dkNET Resources search. From here you can search through a compilation of resources used by dkNET and see how data is organized within our community.
You are currently on the Community Resources tab looking through categories and sources that dkNET has compiled. You can navigate through those categories from here or change to a different tab to execute your search through. Each tab gives a different perspective on data.
If you have an account on dkNET then you can log in from here to get additional features in dkNET such as Collections, Saved Searches, and managing Resources.
Here is the search term that is being executed, you can type in anything you want to search for. Some tips to help searching:
You can save any searches you perform for quick access to later from here.
We recognized your search term and included synonyms and inferred terms along side your term to help get the data you are looking for.
If you are logged into dkNET you can add data records to your collections to create custom spreadsheets across multiple sources of data.
Here are the sources that were queried against in your search that you can investigate further.
Here are the categories present within dkNET that you can filter your data on
Here are the subcategories present within this category that you can filter your data on
If you have any further questions please check out our FAQs Page to ask questions and see our tutorials. Click this button to view this tutorial again.