Dr. Steven Wilhelm, Samantha Coy 2017. Concentrating Viruses by Tangential Flow Filtration. protocols.io https://dx.doi.org/10.17504/protocols.io.hgrb3v6Copy Citation Copied
URL: https://dx.doi.org/DOI:10.17504/protocols.io.hgrb3v6
Authors: Dr. Steven Wilhelm, Samantha Coy
Group: VERVE Net, The Aquatic Microbial Ecology Research Group - AMERG (The Buchan, Zinser and Wilhelm labs), Samantha R Coy's Protocols
Summary: Ultracentrifugation in the WX Ultra Series can support only 30 mL samples at a time, and therefore do not significantly concentrate viruses. Tangential flow filtration enables viral concentration of large volumes that can then be purified using sucrose density gradients. Contact Dr. Steven Wilhelm ([email protected]) or Samantha Coy ([email protected]) for additional information regarding this protocol.