SYSTEM UPDATE: We will be performing system maintenace Saturday September 26 at 9pm to midnight Pacific Time

Searching the RRID Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes
Protocol Name
SILICONE INDUCED GRANULOMA OF BREAST IMPLANT CAPSULE
DOI:DOI:10.17504/protocols.io.bfn4jmgw RRID Copied  
PDF Report How to cite
Eduardo Fleury 2020. SILICONE INDUCED GRANULOMA OF BREAST IMPLANT CAPSULE. protocols.io https://dx.doi.org/10.17504/protocols.io.bfn4jmgw
Copy Citation Copied
Protocol Information

URL: https://dx.doi.org/DOI:10.17504/protocols.io.bfn4jmgw

Authors: Eduardo Fleury

Summary: Objective: To evaluate the ability of BMRI to detect silicone gel bleeding in a prospective observational study including consecutive patients referred for a BMRI scan.Methods: From January 2017 until now, patients referred for BMRI were evaluated in a prospective observational study. Patients who had breast implants were included. BMRI recorded 9 findings according to BI-RADS lexicon and SIGBIC findings, considered equivocal features to detect gel bleeding (GB). Three new original imaging features were added for SIGBIC diagnosis: black drop signal; T2* hypersignal mass; and delayed contrast enhancement, considered as irrevocable signs. The presence of silicones corpuscles was confirmed by percutaneous biopsy or surgical capsulectomy. The accuracy of BMRI SIGBIC findings to predict GB was determined. We also used univariate analysis for the equivocal features for GB diagnosis. The Backward method was applied for a multivariate Logistic Regression model for the equivocal features.

Associated Publications: Fleury EdFC (2020) Silicone Induced Granuloma of Breast Implant Capsule (SIGBIC) diagnosis: Breast Magnetic Resonance (BMR) sensitivity to detect silicone bleeding. PLoS ONE 15(6): e0235050. doi: 10.1371/journal.pone.0235050

Affiliations: MD du FLE tele-radiologia

External URL: http://medRxiv 2020.01.15.20017350; doi: https://doi.org/10.1101/2020.01.15.20017350

Version: 1

Publication Date: 2020

Expand All
Usage and Citation Metrics

Coming soon.

Checkfor resource mentions.

Collaborator Network

Coming soon.

Data and Source Information

Source: