Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
Sam Li 2020. MojoSort™ Whole Blood Human CD8 Nanobeads Whole Blood Column Protocol. protocols.io https://dx.doi.org/10.17504/protocols.io.bbujinunCopy Citation Copied
URL: https://dx.doi.org/DOI:10.17504/protocols.io.bbujinun
Authors: Sam Li
Group: BioLegend
Summary: BioLegend MojoSort™ nanobeads work in commonly used separation columns, based on our internal research as well as validation by external testing by academic labs. This simple protocol consists of following the MojoSort™ protocol to label the cells with pre-diluted MojoSort™ reagents and using the columns as indicated by the manufacturer.Note: Due to the properties of our beads, it may be possible to use far fewer beads that with other commercial suppliers. We recommend a titration to find the best dilution factor. However, as a general rule, dilutions ranging from 1:3 to 1:20 for the Nanobeads can be used. Please contact BioLegend Technical Service ([email protected]) if further assistance is needed.
Affiliations: BioLegend
External URL: https://www.biolegend.com/en-us/protocols/mojosort-whole-blood-human-cd8-nanobeads-whole-blood-column-protocol
Version: 2