Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.
Lumei Liu, Youngmi Koo, Boyce Collins, Zhigang Xu, Jagannathan Sankar, Yeoheung Yun 2017. ZWEK alloy fabrication procedure. protocols.io dx.doi.org/10.17504/protocols.io.iepcbdnCopy Citation Copied
URL: https://dx.doi.org/10.17504/protocols.io.iepcbdn
Authors: Lumei Liu, Youngmi Koo, Boyce Collins, Zhigang Xu, Jagannathan Sankar, Yeoheung Yun
Summary: Melting and alloying operations were performed in a low carbon steel crucible in an inert ultra-high purity argon environment, preventing the oxidation reactions of molten Mg. High purity Mg (99.97%) was heated to 710°C for 10 minutes until the slug was completely melted. Each alloying element was added separately and kept for 10 minutes before additional alloy was added to ensure complete dissolution of all alloying elements. Automated stirring was applied for 15 minutes to ensure a homogeneous distribution of elements throughout the melt. The melt was then raised to 730 °C, held for 15 minutes and then poured into a steel tube mold. A solution heat treat was carried out on the as-cast alloy at 510 °C for 10 h before it was extruded. The extrusion was conducted with an extrusion ratio 10, extrusion temperature 400 ºC and ramp speed 1 mm/s.
Associated Publications: Liu L, Koo Y, Collins B, Xu Z, Sankar J, Yun Y (2017) Biodegradability and platelets adhesion assessment of magnesium-based alloys using a microfluidic system. PLoS ONE 12(8): e0182914. doi: 10.1371/journal.pone.0182914
Affiliations: National Science Foundation-Engineering Research Center for Revolutionizing Metallic Biomaterials, North Carolina Agricultural and Technical State University, Greensboro, North Carolina, USA FIT BEST Laboratory, Department of Chemical, Biological, and Bioengineering, North Carolina Agricultural and Technical State University, Greensboro, North Carolina, USA, National Science Foundation-Engineering Research Center for Revolutionizing Metallic Biomaterials, North Carolina Agricultural and Technical State University, Greensboro, North Carolina, USA FIT BEST Laboratory, Department of Chemical, Biological, and Bioengineering, North Carolina Agricultural and Technical State University, Greensboro, North Carolina, USA, National Science Foundation-Engineering Research Center for Revolutionizing Metallic Biomaterials, North Carolina Agricultural and Technical State University, Greensboro, North Carolina, USA FIT BEST Laboratory, Department of Chemical, Biological, and Bioengineering, North Carolina Agricultural and Technical State University, Greensboro, North Carolina, USA, National Science Foundation-Engineering Research Center for Revolutionizing Metallic Biomaterials, North Carolina Agricultural and Technical State University, Greensboro, North Carolina, USA FIT BEST Laboratory, Department of Chemical, Biological, and Bioengineering, North Carolina Agricultural and Technical State University, Greensboro, North Carolina, USA, National Science Foundation-Engineering Research Center for Revolutionizing Metallic Biomaterials, North Carolina Agricultural and Technical State University, Greensboro, North Carolina, USA FIT BEST Laboratory, Department of Chemical, Biological, and Bioengineering, North Carolina Agricultural and Technical State University, Greensboro, North Carolina, USA, National Science Foundation-Engineering Research Center for Revolutionizing Metallic Biomaterials, North Carolina Agricultural and Technical State University, Greensboro, North Carolina, USA FIT BEST Laboratory, Department of Chemical, Biological, and Bioengineering, North Carolina Agricultural and Technical State University, Greensboro, North Carolina, USA
External URL: https://doi.org/10.1371/journal.pone.0182914
Version: 1
Publication Date: 2017
Expand AllComing soon.
Source: Protocols.io