Searching the RRID Resource Information Network

Our searching services are busy right now. Please try again later

  • Register
X
Forgot Password

If you have forgotten your password you can enter your email here and get a temporary password sent to your email.

X

Leaving Community

Are you sure you want to leave this community? Leaving the community will revoke any permissions you have been granted in this community.

No
Yes
Protocol Name
DOI:10.17504/protocols.io.bisbkean RRID Copied  
PDF Report How to cite
Sarah Reiling, Marie-Michelle Simon, Anne-Marie Roy, Shu-Huang Chen, Josh Quick, Ioannis Ragoussis 2020. SARS-CoV-2 McGill Nextera Flex sequencing protocol_SS_V3_LA1_5uLRT. protocols.io dx.doi.org/10.17504/protocols.io.bisbkean
Copy Citation Copied
Protocol Information

URL: https://dx.doi.org/10.17504/protocols.io.bisbkean

Authors: Sarah Reiling, Marie-Michelle Simon, Anne-Marie Roy, Shu-Huang Chen, Josh Quick, Ioannis Ragoussis

Group: Coronavirus Method Development Community, McGill Genome Centre

Summary: How the Nextera DNA Flex Assay Works The Nextera DNA Flex library prep kit uses a bead-based transposome complex to tagment genomic DNA, which is a process that fragments DNA and then tags the DNA with adapter sequences in one step. After it is saturated with input DNA, the bead-based transposome complex fragments a set number of DNA molecules. This fragmentation provides flexibility to use a wide DNA input range to generate normalized libraries of consistent tight fragment size distribution. Following tagmentation, a limited-cycle PCR adds Nextera DNA Flex-specific index adapter sequences to the ends of a DNA fragment. This step enables capability across all Illumina sequencing platforms. A subsequent Sample Purification Beads (SPB) cleanup step then purifies libraries for use on an Illumina sequencer. The double-stranded DNA library is denatured before hybridization of the biotin probe oligonucleotide pool. PCR Amplicons for Nextera FlexWhen starting with PCR amplicons, the PCR amplicon must be > 150 bp. The standard clean up protocol depletes libraries Therefore, Illumina recommends that amplicons Shorter amplicons can otherwise be lost during the library cleanup step. Tagmentation cannot add an adapter directly to the distal end of a fragment, so a drop in sequencing coverage of ~50 bp from each distal end is expected. To ensure sufficient coverage of the amplicon target region, design primers to extend beyond the target region by 50 bp per end. More information can be found here: https://emea.support.illumina.com/content/dam/illumina-support/documents/documentation/chemistry_documentation/samplepreps_nextera/nextera_dna_flex/nextera-dna-flex-library-prep-reference-guide-1000000025416-07.pdf

Affiliations: McGill University, McGill University, McGill University, McGill University, University of Birmingham, McGill University

Version: 1

Publication Date: 2020

Expand All
Usage and Citation Metrics

Coming soon.

Checkfor all resource mentions.

Collaborator Network

Coming soon.

Data and Source Information

Source: Protocols.io